How do I calibrate my 4100/6100/8100 (N Series) control? Click here for the West 6100, 8100, 4100 (N Series)calibration procedure Tags Controllers West 4100/6100/8100 Series Original N Series Read more about How do I calibrate my 4100/6100/8100 (N Series) control?
It is impossible to change the Hardware Definition code. You are likely in the read only mode instead of the configuration mode or the input jumpers are in t Tags Controllers West 4100/6100/8100 Series Original N Series Read more about It is impossible to change the Hardware Definition code.
Communication Requirements & Settings for N Series 4100, 6100, 8100 Series Controls. 4100, 6100 & 8100 Series Controls In order to communicate with West controllers you will need th Tags Controllers West 4100/6100/8100 Series Original N Series Read more about Communication Requirements & Settings for N Series 4100, 6100, 8100 Series Controls.
Why am I unable to select the input code that I want in the configuration mode? The instrument will only make available for selection, those input codes that match the input type a Tags Controllers West 4100/6100/8100 Series Original N Series Read more about Why am I unable to select the input code that I want in the configuration mode?
Why does my display show [OPEN] instead of the Process Value? This error message indicates that the signal from your sensor is absent. This may be caused by a fau Tags Controllers West 4100/6100/8100 Series Newer P Series Read more about Why does my display show [OPEN] instead of the Process Value?
Why does my display show [HH] instead of the Process Value? This error message indicates that the Process Variable is above the upper limit of the range. For ex Tags Controllers West 4100/6100/8100 Series Newer P Series Read more about Why does my display show [HH] instead of the Process Value?
What is the difference between the Dual Setpoint and Remote Setpoint options? Standard controllers operate with a single target setpoint which is entered from the front panel. Mo Tags Controllers West 4100/6100/8100 Series Newer P Series Read more about What is the difference between the Dual Setpoint and Remote Setpoint options?
Why does my display show [LL] instead of the Process Value? This error message indicates that the Process Variable is below the lower limit of the range. For ex Tags Controllers West 4100/6100/8100 Series Newer P Series Read more about Why does my display show [LL] instead of the Process Value?
Why are the valve motor drive (VMD) outputs limited to 120V AC operation? If the valve motor is driven directly by the controller output relays, the controller outputs are li Tags Controllers West 4100/6100/8100 Series West 2800/3800 Series West 5010 Series Newer P Series West 4400 Series Read more about Why are the valve motor drive (VMD) outputs limited to 120V AC operation?