DaqPRO Data Logger Sample Rates
Sample rates depend on the number and type of inputs selected.
1 Input - Excluding Temperature:
| 4000|2000|500|100|50|25|10|1 | Samples per Second |
| Every: 10 | Seconds |
| Every: 1|10|30 | Minutes |
| Every: 1 | Hour |
| Manual (Operator) |
2-6 Inputs - Excluding Temperature:
| Every: 1|10 | Seconds |
| Every: 1|10|30 | Minutes |
| Every: 1 | Hour |
| Manual (Operator) |
7-8 Inputs - Excluding Temperature:
| Every: 10 | Seconds |
| Every:1|10|30 | Minutes |
| Every: 1 | Hour |
| Manual (Operator) |
1-4 Inputs - Thermocouple:
| Every: 1|10 | Seconds |
| Every: 1|10|30 | Minutes |
| Every: 1 | Hour |
| Manual (Operator) |
5-8 Inputs - Thermocouple:
| Every: 10 | Seconds |
| Every: 1|10|30 | Minutes |
| Every: 1 | Hour |
| Manual (Operator) |
1 Input - RTD:
| Every: 1|10 | Seconds |
| Every: 1|10|30 | Minutes |
| Every: 1 | Hour |
| Manual (Operator) |
2-7 Inputs - RTD:
| Every: 10 | Seconds |
| Every: 1|10|30 | Minutes |
| Every: 1 | Hour |
| Manual (Operator) |
8 Inputs - RTD:
| Every: 1|10|30 | Minutes |
| Every: 1 | Hour |
| Manual (Operator) |